CCF Concentrated Growth Factors
Concentrated Growth Factors (CGF) are autologous blood-derived preparations obtained from a patient's own blood using a controlled centrifugation protocol.
The CGF preparation contains a fibrin matrix with platelets and naturally occurring blood-derived components. Because the preparation originates from the patient's own blood, CGF is considered an autologous preparation.
The CGF protocol is designed to prepare different blood-derived fractions without the addition of exogenous substances during the preparation of the fibrin clot.
CGF is a platelet- and fibrin-containing preparation obtained through a controlled centrifugation process.
Platelets and the resulting fibrin matrix contain naturally occurring biological components, including growth factors and signalling proteins involved in normal physiological tissue-repair processes.
Depending on the preparation protocol, CGF can be processed into different forms, such as a fibrin clot, fibrin membrane or liquid fraction, for use by appropriately trained healthcare professionals.
The selected preparation and clinical application depend on the procedure, individual patient and intended purpose of the medical devices used.
The MEDIFUGE is designed for the controlled separation of blood components and preparation of CGF fibrin using dedicated blood collection tubes.
System characteristics include:
Processing of up to eight dedicated blood tubes
Predefined centrifugation programmes
Microprocessor-controlled centrifugation
Controlled processing of autologous blood
Removable and autoclavable components
Preparation of CGF fibrin without the addition of exogenous substances
The device must always be used according to the manufacturer's current Instructions for Use and intended purpose.
Platelets, fibrin and blood-derived signalling molecules naturally participate in the body's physiological tissue-repair processes.
CGF provides an autologous fibrin matrix containing platelets and other blood-derived components. This matrix may be incorporated by healthcare professionals into selected clinical or surgical procedures.
CGF should be regarded as an adjunct within a clinical procedure and not as an independent treatment or guarantee of tissue regeneration, healing or a particular clinical result.
Clinical outcomes depend on multiple factors, including the patient's condition, treatment indication, procedural technique and individual biological response.
CGF is characterised by:
Autologous origin
Preparation from the patient's own blood
Formation of a fibrin matrix
Presence of platelets and naturally occurring blood-derived components
Preparation without the addition of exogenous substances within the CGF protocol
Possibility of producing fibrin-based preparations for selected clinical applications
The fibrin matrix may provide a biological structure that can be incorporated into selected surgical and regenerative procedures at the discretion of the treating healthcare professional.
CGF and related autologous platelet- and fibrin-based preparations have been used and investigated across several medical and dental disciplines.
Depending on the specific device, intended purpose and applicable regulations, areas in which these preparations may be used or investigated include:
Dentistry
Implantology
Periodontology
Oral surgery
Maxillofacial surgery
Orthopaedics
Sports medicine
Dermatology
Cosmetic and reconstructive procedures
General surgery
Wound care
Clinical evidence, regulatory status and approved indications may differ considerably between applications.
The presence of an application in scientific literature does not automatically mean that the application is an approved indication for every CGF device or protocol.
Autologous fibrin preparations such as CGF may be incorporated into selected dental and oral-surgical procedures.
Applications of platelet- and fibrin-based preparations have been described in areas such as:
Periodontal procedures
Implantology
Oral and maxillofacial surgery
Bone-related surgical procedures
Soft-tissue procedures
Sinus augmentation procedures
Ridge augmentation procedures
The decision to use CGF and the selected protocol remains the responsibility of the treating healthcare professional.
The use of CGF does not guarantee improved bone formation, tissue regeneration, implant success or other specific clinical outcomes.
Autologous platelet- and fibrin-based preparations have also been investigated in musculoskeletal and sports-medicine procedures.
Research has explored their use in procedures involving structures such as tendons, muscles and joints.
Evidence, preparation protocols and outcomes differ between indications, and CGF should therefore not be presented as a proven treatment for every musculoskeletal condition.
Autologous platelet-based preparations have been investigated in patients with lateral epicondylitis.
Clinical results may vary depending on factors including the type of preparation, patient population, severity of the condition and treatment protocol.
CGF should therefore not be presented as a guaranteed treatment or cure for lateral epicondylitis.
Its potential use should be evaluated individually by an appropriately qualified healthcare professional.
Autologous platelet- and fibrin-based preparations are also used and investigated within dermatology, cosmetic surgery and medical aesthetics.
Protocols used in aesthetic medicine may differ from surgical protocols because the treatment objectives, tissue characteristics and methods of application are different.
Research has investigated platelet-derived preparations in relation to physiological processes involving skin and connective tissue. However, the degree of evidence varies between procedures and indications.
No particular aesthetic result, collagen increase, wrinkle reduction, skin regeneration or other outcome can be guaranteed.
Any dermatological or aesthetic application should be performed by appropriately qualified professionals and in accordance with the intended purpose of the devices used.
CGF is an autologous biological preparation, but this does not mean that every procedure is free of risk or suitable for every patient.
As with any medical or surgical procedure, suitability must be evaluated individually.
Healthcare professionals should consider, where applicable:
The patient's medical history
Current medication
Relevant contraindications
Treatment indication
Procedural risks
Device-specific warnings
Applicable professional guidelines
Current scientific evidence
The manufacturer's current Instructions for Use always take precedence.
CGF systems and associated medical devices are intended for use by appropriately qualified and trained healthcare professionals.
Patient selection, diagnosis, indication, preparation technique and clinical application remain the responsibility of the treating healthcare professional.
Healthcare professionals should use CGF only when its use is consistent with:
The manufacturer's intended purpose
The current Instructions for Use
Relevant contraindications and warnings
Applicable national and European legislation
Their own professional competence and clinical judgement
Autologous platelet- and fibrin-based preparations continue to be the subject of scientific and clinical research.
The level and quality of available evidence may differ substantially between clinical applications.
References to published studies, case reports or clinical experience should not be interpreted as proof that a particular application is approved, effective for every patient or superior to established treatment alternatives.
Clinical decisions should be based on the individual patient, current scientific evidence, professional guidelines and the regulatory status of the devices concerned.
The information provided on this website is intended for general informational and professional educational purposes and is primarily directed at qualified healthcare professionals.
Clinical applications, indications and outcomes associated with CGF may vary depending on the patient, procedure, treatment protocol, device configuration and applicable local regulations.
References to clinical use, scientific publications or investigated applications do not imply that every application is approved, clinically established or suitable for every patient.
CGF and related medical devices should only be used by appropriately trained healthcare professionals and in accordance with the manufacturer's current Instructions for Use, intended purpose, contraindications, warnings and applicable regulatory requirements.
The information provided on this website does not constitute medical advice, does not replace professional clinical judgement and does not guarantee any specific therapeutic, regenerative, aesthetic or clinical outcome.
Clinical evidence and regulatory status may vary by indication and jurisdiction.
Where information provided on this website differs from the manufacturer's current Instructions for Use or official regulatory documentation, the manufacturer's approved documentation shall prevail.